| SOLD - Metrohm Titration System with 730 Sample Changer, 722 Rod Stirrer, 751 GPD Titrino, and Other Accessories |
|
SOLD - Clean and decommissioned at the time of acquisition, this previously-owned Metrohm Titration System is composed of the following units/parts:
1. Metrohm 730 Sample Changer, P/N 6.2041.380, with a a tower, a pump connection (note: no pump), and two stirrer connections, featuring:
- One (1) each 14-position sample tray, P/N 6.2041.380; clean with slight stain due to previous use but does not affect the operational integrity of the unit. This sample rack accepts 150mL beakers (not included, but are available for an extra charge).
- One (1) each Metrohm 722 Rod Stirrer, P/N 2.722.0020, mounted on the tower lift; good condition and clean. The propeller stir shaft (P/N 6.1909.010) is intact. Stirring speed for a new unit (measured in 30mL water with one electrode) is rated by Metrohm at 440 to 2800 rpm.
- Ports built into the system: (a) one remote control socket connection (female) for a 25-pin cable; (b) two stirrer sockets; (c) one 37-pin external bus socket (female) on the back of the main unit; (d) one external bus address selector; (e) one 25-pin male port connection; and (f) one keyboard port.
- Tube lines - all flushed out and cleaned.
- Tower, guide chain, distribution head, valve and pump of the 730 sample changer - all clean and intact.
- Built-in beaker indicator/sensor to detect a beaker in front of the tower after each MOVE position.
- Electrical Requirements: 115VAC, 50/60Hz, 40VA.
The 730 Sample Changer has the following capabilities:
- Interface control - sends signal remotely to control peripheral devices or transmit data via the RS-232 serial interface.
- Interface scan - displays the condition of the remote control lines or the received data of the serial interface.
- Report printing.
- Dosimat control to enter a volume to be dispensed or press a function to execute on the keyboard.
- On/off stirrer control and pump control.
- Definition of the first sample position of a series.
- MOVE position to place a beaker in front of the tower.
- Lift control.
2. Metrohm SC Controller Keyboard (pendant), P/N 6.2142.010, featuring a control panel with digital display window.
3. Metrohm 751 GPD Titrino, type 1.751.0010, featuring:
- Digital display window for values.
- Two data storage and retrieval methods: (a) built-in internal memory method, and (b) external memory method via a memory card (not included; however, the unit has a memory card slot).
- Knob control.
- One (1) each Metrohm 751 GPD Titrino keyboard, P/N 6.2132.060, with built-in plug/connector.
- Built-in ports: (a) two ports for Dosimat; (b) one port for stirrer socket; (c) keyboard port; and remote port (25-pin female socket; and other ports, as shown on the photo. This model can connect to one or two Metrohm 685 titrating burets (one buret for acid/base titrations, another for precipitation titration). A third connection is optional for a Karl Fischer moisture determination.
- Capability for linking titration methods (e.g., multiple measurements and titrations, alkalinity and chloride, sulfate and chloride, alkalinity and hardness) or titrating burets for the same sample.
- One (1) each power cord.
- Electrical Requirements: 115V, 50/60Hz, 15W.
4. Metrohm 685 Dosimat, featuring a 10mL Exchange Unit with the following parts/accessories:
- A rating plate of 1.685.0010.
- One (1) each amber reagent bottle, P/N 6.1608.023, with siphon (P/N 6.1602.100), screw cap (P/N 6.1446.080), and SGJ clamp (P/N 6.2023.020).
- One (1) each amber light protection (P/N 5.1563.000) with glass cylinder inside.
- Tube lines
- One (1) each drying tube (glassware), P/N 6.1609.000.
- Two (2) each glass holder (P/N 6.1561.00), identification plate (P/N 6.2244.000), and plate holder (P/N 6.2046.050), all built into the base plate. Each glass holder has a plastic tube.
- Retaining clips (P/N 6.2043.000), for reagent bottle.
- Nut (P/N 6.2044.00) for glass cylinder.
- 9-pin remote control port connection (male).
5. A second Metrohm 685 Dosimat unit, featuring a 20mL Exchange unit with the following parts/accessories:
- A rating plate of 1.685.0010.
- One (1) each amber reagent bottle, P/N 6.1608.023, with siphon (P/N 6.1602.100), screw cap (P/N 6.1446.080), and SGJ clamp (P/N 6.2023.020).
- One (1) each amber light protection with glass cylinder inside.
- Tube lines
- One (1) each drying tube (glassware), P/N 6.1609.000.
- Two (2) each glass holder (P/N 6.1561.00), identification plate (P/N 6.2244.000), and plate holder (P/N 6.2046.050), all built into the base plate. Each glass holder has a plastic tube.
- Retaining clips (P/N 6.2043.000), for reagent bottle.
- Nut (P/N 6.2044.00) for glass cylinder.
- 9-pin remote control port connection (male).
6. One (1) each Remote Box for BK730 Sample Changer with six (6) remote ports, indicator lights, and priming switches for each port. The box also includes a cable and a power cord.
7. Brinkmann Workcell Software, version 4.3
Optional Accessories:
- One (1) each 5mL Exchange Unit (photo available upon request).
- One (1) each 728 Magnetic Stirrer with accessories (photo available upon request) and spare parts of different configurations.
- Other accessories (photos available upon request).
Note: LabCommerce also carries a second Metrohm 730 Sample Changer, P/N 6.2041.390, with a slightly different configuration of parts/accessories. Designed as a 16-position sample tray, this unit can accommodate 120mL beakers. Photos and quotations are available upon request.
|

 |
| Item Code: |
ANA-1593 |
| Model: |
BK730 |
| Manufacturer: |
Metrohm (Brinkmann Instruments) |
| Availability: |
Sold |
| Selling Price: |
Sold |
|

 |
| Electrical Specifications (730 Sample Changer): | 115V, 50/60Hz, 40VA | | Other Specifications: Metrohm Sample Changer 730: | - Titrator Capability: Compatible with models 716, 719, 751 (included with this system), and 785.
- Configuration: Circular
- Interchangeable beaker tray
- Number of Samples: 14 (another Sample Changer 730 with 16 positions is available).
- Beaker Size: 150mL
- Stirrer: Propeller and/or magnetic (the available system has a propeller stirrer).
- Dual Working Station (optional)
- Built-in pump (the available system does not have an external pump).
- Rinse Capabilities: Dip and/or mist rinse
- Computer-Controlled, RS-232
- Multiple measurement and titration capability
- Rinses/reconditions electrodes
| | Specifications: Metrohm Titrino Titrator GPD 751: | - Real Time Curve Display
- Titrating Burets: 3
- Memory Card Slot (Note: The available unit does not include a memory card.)
- Programmable stirrer
- End-point-seeking Titrations: 9 EPs
- End-point Titrations: 2 EPs
- Compatible with Karl Fischer Titrators
- Direct Measurement: pH, mV and temperature
- pH Stat
- External data storage on a PC
- 8-line display
- Resolution: 0.2mV or 0.003pH
- Resolution (mL): 1/10,000 of Buret Volume
- Electrode Inputs: 2 High Imped., 1 Reference, 1 Temperature, 1 Polarized (KF)
. |
|

 |
| Call us today for details. |
|
| |