730 Sample Changer with SC Controller.
Fully operational / Clean / Flushed-out tube lines.

  >> View More Photos   
Home > Laboratory Equipment > Analytical Instruments
 
NOW SOLD PIECE BY PIECE - SOME ITEMS NO LONGER AVAILABLE - Metrohm Titration System with 730 Sample Changer (50 Positions), 765 Dosimats, 685 Dosimat, and Accessories

NOTE: This system is now being sold on a piece-by-piece basis, and the following are no longer available: 799 GPT Titrino, 765 Dosimats, and 751 GPD Titrino . Please inquire about availability of the units/parts listed below, as some of the parts may no longer be available. New photos are also available upon request.

The 730 Sample Changer has the following capabilities:

  • Interface control - sends signal remotely to control peripheral devices or transmits data via the RS-232 serial interface.

  • Interface scan - displays the condition of the remote control lines or the received data of the serial interface.

  • Report printing.

  • Dosimat control to enter a volume to be dispensed or press a function to execute on the keyboard.

  • On/off stirrer control and pump control.

  • Definition of the first sample position of a series.

  • MOVE position to place a beaker in front of the tower.

  • Lift control.


Clean and decommissioned at the time of acquisition, these previously-owned Metrohm 730 Sample Changer and Titration Systems include the following units/parts:

1. Metrohm 730 Sample Changer, Type 1.730.0010/28160, 100-120VAC/200-240VAC, 50/60 Hz, 40 VA. It includes the following parts:
  • 50-position sample tray (P/N 6.9920.024) with additional two (2) slots for custom-sized beakers.

  • Tower/guide chain with five (5) tube lines (all flushed out and clean).

  • Pump connector (no pump).

  • Magnetic stirrer.

  • Ports on the rear and on the side: (a) external bus, (b) power, (c) address, (d) RS 232, (e) Dosimat ports, and (f) keyboard/SC Controller port.

  • Power cord.


2. Metrohm SC Controller Keyboard (pendant), P/N 6.2142.010, featuring a control panel with digital display window.

3. (SOLD - no longer available) - Metrohm 799 GPT Titrino, type 1.799.0010, S/N 03176, featuring:

  • Digital display window for values.

  • Two data storage and retrieval methods: (a) built-in internal memory method, and (b) external memory method via a memory card (two memory cards are included). See memory card slot in front of the unit.

  • Knob control.

  • One (1) each Metrohm 799 GPT Titrino (SOLD - NO LONGER AVAILABLE) keyboard, P/N 6.2132.100, with built-in plug/connector.

  • Built-in ports: (a) two RS 232 ports, (b) one keyboard port, (c) one remote control port, (d) two ports for Dosimats; e) one stirrer port, (f) one power port, and (g) six other ports.

  • Capability for linking titration methods (e.g., multiple measurements and titrations, alkalinity and chloride, sulfate and chloride, alkalinity and hardness) or titrating burets for the same sample.

  • One (1) each power cord.

  • One (1) each 5mL Exchange Unit (base plate), P/N 6.3026.110, S/N 11180083, with the following parts: (a) two plastic tube holders; (b) one Idrolyte Electrode, P/N 6.0224.100, pH1...11/0...60



Item Code: ANA-1994
Model: 730
Manufacturer: Metrohm (Brinkmann Instruments)
Availability: Sold
Selling Price: Sold


Other Specifications: Metrohm Sample Changer 730:
  • Titrator Capability: Compatible with models 716, 719, and 785.

  • Configuration: Circular

  • Interchangeable beaker tray

  • Number of Sample Positions: 50.

  • Beaker Size: 150mL (two slots).

  • Stirrer: Propeller and/or magnetic (the available system has a propeller stirrer).

  • Built-in pump (the available system does not have an external pump).

  • Rinse Capabilities: Dip and/or mist rinse

  • Computer-Controlled, RS-232

  • Multiple measurement and titration capability

  • Rinses/reconditions electrodes.
Electrical Specifications (730 Sample Changer):100-120VAC/200-240VAC, 50/60Hz, 40VA.
(SOLD) - Metrohm Titrino Titrator GPD 799:
  • Real Time Curve Display

  • Titrating Burets: 3

  • Memory Card Slot (Note: The available unit does not include a memory card.)

  • Programmable stirrer

  • End-point-seeking Titrations: 9 EPs

  • End-point Titrations: 2 EPs

  • Compatible with Karl Fischer Titrators

  • Direct Measurement: pH, mV and temperature

  • pH Stat

  • External data storage on a PC

  • 8-line display

  • Resolution: 0.2mV or 0.003pH

  • Resolution (mL): 1/10,000 of Buret Volume

  • Electrode Inputs: 2 High Imped., 1 Reference, 1 Temperature, 1 Polarized (KF)
.


  Call us today for details.


 